Details

    • Type: Improvement
    • Status: Done
    • Priority: Medium
    • Resolution: Done
    • Affects Version/s: 2.0.0
    • Fix Version/s: 2.0.1
    • Component/s: PMM Agent
    • Labels:
      None

      Description

      The current problem: Slow log rotation works, but the only one slow log file is presented, there is no any old slow log file exist.

      Solution: Keep one old slow log file, there should be slow log file and one old slow log file.

      Original report: From Michael Coburn

      Yes we want one extra file , so we will always have two files present

        Smart Checklist

          Attachments

            Activity

              People

              • Assignee:
                Unassigned
                Reporter:
                alexey.palazhchenko Alexey Palazhchenko
              • Votes:
                0 Vote for this issue
                Watchers:
                1 Start watching this issue

                Dates

                • Created:
                  Updated:
                  Resolved:

                  Time Tracking

                  Estimated:
                  Original Estimate - 0 minutes
                  0m
                  Remaining:
                  Remaining Estimate - 0 minutes
                  0m
                  Logged:
                  Time Spent - 2 hours, 40 minutes
                  2h 40m